Planning and scope
The property type, occupancy, access arrangements, previous reports and any operational restrictions are confirmed.
What happens during an Electrical Installation Condition Report—from the initial visual inspection through to testing, classification codes and final reporting.
An Electrical Installation Condition Report is produced after the fixed electrical installation has been inspected and tested by a competent electrical professional.
The purpose is to establish whether the installation is safe for continued use and to identify deterioration, damage, defects or unsafe alterations that may require investigation or remedial work.
The inspection covers the permanent installation rather than portable appliances. It can include consumer units, distribution boards, final circuits, sockets, lighting, protective devices, earthing, bonding and fixed equipment.
The exact sequence depends on the property, access and circuit arrangements, but the inspection normally follows these stages.
The property type, occupancy, access arrangements, previous reports and any operational restrictions are confirmed.
Accessible parts are checked for damage, deterioration, overheating, unsuitable equipment and unsafe alterations.
Circuits are safely isolated before dead testing. Sensitive equipment may need to be shut down first.
Tests can include conductor continuity, ring-final continuity, insulation resistance and polarity.
Live verification can include loop impedance, RCD testing, fault current and functional checks.
Results are assessed, observations are classified and the final EICR is prepared and issued.
Visual inspection often identifies defects before electrical testing begins and guides the extent of further examination.
Enclosures, protective devices, circuit identification and signs of overheating or damage are examined.
The presence and condition of the earthing conductor and protective bonding are checked.
Sockets, switches and lighting accessories are checked for damage, looseness and heat damage.
Accessible wiring is inspected for deterioration, poor support and mechanical damage.
Equipment is assessed for exposure to moisture, heat, impact, dust and other conditions.
Alterations and additions are examined for incorrect installation or unsuitable protection.
Testing confirms whether conductors, insulation and protective devices can operate safely and as intended.
The classification code indicates the level of safety concern and the action required.
An immediate risk of injury. Immediate action is required to remove or isolate the danger.
A defect that could become dangerous under fault conditions or foreseeable use.
An issue requiring further investigation without delay because safety cannot be confirmed.
An improvement is recommended, but this code alone does not make the report unsatisfactory.
A report containing a C1, C2 or FI observation will normally be assessed as unsatisfactory. C3 observations alone do not normally make the report unsatisfactory.
View EICR remedial worksYes. Safe isolation is an essential part of the procedure. Individual circuits normally need to be switched off so dead tests can be completed safely and accurately.
Where practical, interruptions are managed circuit by circuit. Some properties may experience periods where the entire installation is without power.
Computers, alarms, internet equipment, heating controls, refrigeration and other sensitive equipment should be considered before testing starts.
Every installation is different. These are broad guides rather than fixed appointment times.
A guide where access is straightforward and the installation is reasonably documented.
Time varies according to circuit quantity, access and installation condition.
Larger or operational premises may require phased testing or additional visits.
The engineer reviews the observations and test results before completing the Electrical Installation Condition Report.
A satisfactory report confirms that no defects have been identified which make the installation unsatisfactory for continued use at the time of inspection.
Where the report is unsatisfactory, the observations and required remedial work or further investigation should be identified clearly.
Useful answers about the testing procedure, power interruptions, coding and completed reports.
An EICR combines visual inspection, safe isolation, appropriate dead and live electrical testing, assessment of the results and preparation of the final Electrical Installation Condition Report.
Yes. Parts of the installation normally need to be safely isolated while dead testing is completed. Testing is planned to reduce disruption wherever practical.
The time depends on the size, condition and complexity of the installation. A small flat may take several hours, while larger homes, HMOs and commercial premises can take considerably longer.
Usually yes, although the engineer needs access to the consumer unit, sockets, switches, lighting points and other accessible parts of the fixed installation.
No. An EICR examines the fixed electrical installation. Portable appliances require separate portable appliance testing where appropriate.
C1 means danger is present, C2 means potentially dangerous, C3 means improvement is recommended and FI means further investigation is required without delay.
Age alone does not determine the outcome. The condition, protective devices, enclosure, earthing arrangements and suitability of the equipment are considered.
The defects are recorded with the appropriate classification codes. Where the report is unsatisfactory, remedial work or further investigation is required.
Where an EICR has been registered with The Electrical Safety Council Ltd, its recorded details may be checked through the TESC public EICR register.
Tell us the property type, location, size, occupancy and whether the inspection is for a landlord, homeowner, managing agent or commercial business.